<?xml version="1.0" encoding="UTF-8"?>
<record
    xmlns:xsi="http://www.w3.org/2001/XMLSchema-instance"
    xsi:schemaLocation="http://www.loc.gov/MARC21/slim http://www.loc.gov/standards/marcxml/schema/MARC21slim.xsd"
    xmlns="http://www.loc.gov/MARC21/slim">

  <leader>01351nam a2200121Ia 4500</leader>
  <controlfield tag="008">231221s9999    xx            000 0 und d</controlfield>
  <datafield tag="041" ind1=" " ind2=" ">
    <subfield code="a">English</subfield>
  </datafield>
  <datafield tag="100" ind1=" " ind2=" ">
    <subfield code="a">Varsha Thombare.</subfield>
  </datafield>
  <datafield tag="245" ind1=" " ind2="0">
    <subfield code="a">Technical loss evaluation of agricultural 11kv feeder under cesc, Mysore</subfield>
    <subfield code="b">Senthil Vadivu, U.</subfield>
  </datafield>
  <datafield tag="260" ind1=" " ind2=" ">
    <subfield code="c">2018-2019</subfield>
    <subfield code="b">PES University</subfield>
    <subfield code="a">Bengaluru</subfield>
  </datafield>
  <datafield tag="510" ind1=" " ind2=" ">
    <subfield code="a">The objective of this project is Technical Loss Evaluation the 11kV feeder, to implement energy efficiency measure in agriculture sector. It involves establishing a baseline data for measuring the present operating efficiency of agricultural pumpsets in the 11kV Hoskote feeder in the jurisdiction of Chamundeshwari Electricity Supply Company Ltd, MYSURU and the technical loss of the feeder by Power system analysis (Load Flow analysis) and recommend new energy efficient pump replacements of inefficient pumpsets to improve the energy efficiency of the 11kV Hoskote feeder and the remedy for reduction of technical loss of the network, thereby improving the performance of the irrigation pumpsets and optimising the technical loss of the network. To minimise the technical losses evaluation of 11kV Hoskote feeder, the network is reconfigured by adopting Particle Swarm Optimization Algorithm. The study requires complete details of entire 11kV feeder i.e., operational parameters as </subfield>
  </datafield>
  <datafield tag="942" ind1=" " ind2=" ">
    <subfield code="c">CD</subfield>
  </datafield>
  <datafield tag="999" ind1=" " ind2=" ">
    <subfield code="c">237105</subfield>
    <subfield code="d">237105</subfield>
  </datafield>
  <datafield tag="952" ind1=" " ind2=" ">
    <subfield code="r">2024-01-26 00:00:00</subfield>
    <subfield code="l">0</subfield>
    <subfield code="p">CD7232</subfield>
    <subfield code="w">2024-01-26</subfield>
    <subfield code="y">CD</subfield>
    <subfield code="1">0</subfield>
    <subfield code="4">0</subfield>
    <subfield code="7">0</subfield>
    <subfield code="0">0</subfield>
    <subfield code="a">ML</subfield>
    <subfield code="b">ML</subfield>
    <subfield code="d">0000-00-00</subfield>
    <subfield code="E">EE/PG</subfield>
    <subfield code="G">RS</subfield>
    <subfield code="F">1</subfield>
    <subfield code="V">0</subfield>
  </datafield>
</record>
