01521nam a2200133Ia 4500008004100000041001200041100001600053245013500069260005200204510100500256942000701261999001901268952010001287231221s9999 xx 000 0 und d aEnglish aHemanth, J. 0aComparative study of multistory RC building with and without floating columns using construction sequential analysisbRamesh, B V. cSept 2018 - Jul 2019bPES UniversityaBengaluru aIn recent times due to architectural requirements, the structured outcome is more flexible, to satisfy these requirements we need to introduce floating columns. These floating columns are vertical members which rest on beams and where beams transfer the load to columns below it. In present study comparison is made between multistorey buildings having with and without floating columns are analysed in a single step using software on assumption that frames are subjected to design loads only but the real-time, procedure varies as loads are applied in various construction stages on frames and construction sequence accurately represents every floor, and it is expected to yield the most exact analysis results. In this present work model 1 and 2 of with and without floating columns buildings are considered to compare the work of analytical results such as story drift, displacements, story stiffness, base shear,bending moment and shear force etc. they are carried out using Normal linear static cCD c237163d237163 r2024-01-26 00:00:00l0pCD7277w2024-01-26yCD10407000aMLbMLd0000-00-00ECivilGRSF1V0