000 01353nam a2200121Ia 4500
008 231221s9999 xx 000 0 und d
041 _aEnglish
100 _aIsmat Afreen Mazumder.
245 0 _aStudy on static and dynamic response of RC twin flue chimney
_bRamesh, B V.
260 _cSept 2018 - Jul 2019
_bPES University
_aBengaluru
510 _aIn the present study, a reinforced concrete twin flue chimney of a super critical thermal plant corresponding to an installed capacity of 2 x 800 MW is considered. The modelling and analysis of the RC twin flue chimney is carried out using STAAD.Pro V8i. The superstructure of the twin flue chimney is modelled using plate elements and the substructure (foundation) is modelled using solid elements. Wind load and seismic load are considered for the study. Modal analysis is carried out to find the mode shape which is used for the computation of across wind load. Along wind load and across wind load are computed by using Random Response Method and Simplified Method as per IS 4998 (Part 1): 1992. Seismic analysis is carried out using response spectrum method. Static analysis and p-? analysis of the twin flue chimney model are carried out for load combinations. After analyzing the chimney for all the load combinations, results for serviceability conditions such as deflection, later
942 _cCD
999 _c237156
_d237156